IR Value Chart | IR Value Table | IR Value of Motor | IR Value Full Form | IR Value of Transformer

IR stands for Insulation Resistance — the resistance offered by insulating materials to prevent current leakage. Measured in Megaohms (MΩ), it’s a vital parameter for ensuring the safety of motors, transformers, and cables.

    Why is IR Testing Important?

    Insulation resistance testing helps detect moisture ingress, insulation aging, or damage. It ensures safe operation, prevents hazards, and meets international safety standards.

    What is IR Value?

    IR Full Form: Insulation Resistance
    IR Value is the resistance to leakage current measured in using an Insulation Resistance Tester (Megger).

    Factors Affecting IR

    • Moisture ingress
    • Heat
    • Mechanical damage
    • Contamination
    • Aging

    Low IR values can cause leakage, short circuits, fire, or equipment failure.

    IR Testing Ensures:

    • Safe operation
    • Preventive maintenance
    • Early fault detection

    IR Value Chart

    Rated Equipment Voltage Test Voltage (DC) Min. IR Value Remarks
    Up to 250 V500 V≥ 1 MΩControl cables, small equipment
    251–500 V500 V≥ 1 MΩLV power circuits
    501–1000 V1000 V≥ 1 MΩLV panels, feeders
    1.1–11 kV2500 V≥ 5 MΩMV motors, transformers
    11–33 kV5000 V≥ 10 MΩHV switchgear, XLPE cables
    Above 33 kV5000 V+OEM StandardPI/DAR ratio may be used

    IR Value of Motors

    New motors: ≥ 100 MΩ.
    Used motors: IEEE 43 formula → IR (MΩ) = (Rated kV + 1) × 1 MΩ
    Example: 6.6 kV motor → IR ≥ 7.6 MΩ.

    IR Value of Transformers & Cables

    Equipment Type Test Voltage Test Between Purpose
    Power Cables500V–5kVConductor to Earth, Phase to PhaseDetect insulation failure
    Motors/Generators1–5kVWinding to Earth, Phase to PhaseCheck winding insulation
    Transformers1–5kVHV to Earth, LV to EarthVerify dielectric strength
    Lighting Circuits500 VLine to Neutral, Line to EarthAvoid short circuits

    Instruments Used for IR Measurement

    • Megger — analog/digital insulation tester
    • Digital IR Testers — auto-ranging, memory, Bluetooth
    • Analog Testers — rugged, field-friendly
    • Multifunction Testers — IR + RCD, loop, voltage
    • PI/DAR Testers — for advanced insulation analysis
    • Online IR Monitoring — real-time checks without shutdown
    IR Value Chart
    Example IR Value Chart

    IR Testing Procedure (Summary)

    1. De-energize & isolate system
    2. Discharge stored energy
    3. Connect megger correctly
    4. Select proper test voltage
    5. Apply voltage for ≥ 60 seconds
    6. Record readings in MΩ

    Frequently Asked Questions (FAQ)

    What is the full form of IR?

    Insulation Resistance.

    What is a good IR value?

    Above 1 MΩ is generally considered safe.

    How often should IR tests be done?

    During commissioning, scheduled maintenance, and after repairs.

    What does low IR indicate?

    Possible moisture ingress, insulation aging, or faults.

    What instruments are used?

    Megger, Digital IR Tester, PI/DAR Tester, Multifunction Tester.